Schneider Electric

Schneider Electric LX1G4SKUEN Control module,TeSys Giga,100-250V AC/DC,for LC1G400-500/4P standard version

(No reviews yet) Write a Review
SKU:
LX1G4SKUEN
MPN:
LX1G4SKUEN
Condition:
New
Operating Altitude:
9842.52 ft (3000 m) without derating || 5000 m with derating factor
Ip Degree Of Protection:
IP20 IEC 60529
Quantity Per Set:
1
Mercury Free:
Yes
Device Short Name:
LX1G
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Country of Origin:
China
Range:
TeSys
Inrush Power In W:
690.0 W DC
Rohs Exemption Information:
Yes
Halogen Content Performance:
Halogen free plastic parts product
Ambient Air Temperature For Operation:
-25-60°C
Maximum Operating Rate:
600 cyc/mn 60°C
Pollution Degree:
3 IEC 60947-1
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Standards:
EN/IEC 60947-4-1 || UL 60947-4-1A || CSA C22.2 No 60947-4-1
Hold-In Power Consumption In W:
6.2-6.2 W DC
Connections - Terminals:
control circuit push-in termination 1 0.2-2.5 mm² solid stranded without cable end sleeve AWG 26...AWG 12 || control circuit push-in termination 1 0.25-2.5 mm² flexible with cable end sleeve AWG 24...AWG 14 || control circuit push-in termination 2
Mechanical Durability:
5 Mcycles
Depth:
93.0 mm
Eu Rohs Directive:
Compliant with Exemptions
Environmental Disclosure:
ENVPEP2105013
China Rohs Regulation:
X
Control Circuit Voltage Limits:
operational 0.8...1.1 Uc 60°C) || drop-out 0...0.45 Uc 60°C)
Circularity Profile:
ENVEOLI2105013
Inrush Power In Va:
880-880 VA 240 V AC, 60 Hz
Poles Description:
4P
Coil Technology:
built-in bidirectional peak limiting
Ambient Air Temperature For Storage:
-60-80°C
Pvc Free:
Yes
[Uc] Control Circuit Voltage:
100...250 V AC/DC 50/60 Hz
Electromagnetic Compatibility:
EMC immunity conforming to IEC 60947-4-1 || emission tests criteria A conforming to IEC 60947-4-1 || immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 || voltage dips and interruptions immunity tes
Operating Time:
20...35 ms opening || 40...55 ms closing
Sustainable Offer Status:
Green Premium product
Product Compatibility:
LC1G400...500
Hold-In Power Consumption In Va:
11.0-11.0 VA 240 V AC, 60 Hz
Range Compatibility:
TeSys G LX1G contactor coil
Product Or Component Type:
contactor coil
$240.00

Description

It is a 100-250V AC/DC control module for 4 poles TeSys Giga 400-500 contactor (standard version). Coil designed for less energy consumption and wider voltage band-width, connection by spring terminal. It allows contactor operation with high AC-3 operating rates until 600 cycles/hour and environments until 60°C. Control module has connectors for connecting the coil control A1, A2 circuit, pole status and diagnostic signaling circuits. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It is accessible from the front and maintained with very low down times. Unique QR code provides quick access to complete product data.
View AllClose