Schneider Electric

Schneider Electric PJL36060U33A Circuit breaker, PowerPacT P, 600A, 3 pole, 600VAC, 25kA, lugs, Micrologic 5.0, 80%

(No reviews yet) Write a Review
SKU:
PJL36060U33A
MPN:
PJL36060U33A
Condition:
New
Control Type:
toggle
Poles Description:
3P
Mercury Free:
Yes
Mounting Support:
lug
Rohs Exemption Information:
Yes
Product Or Component Type:
circuit breaker
Environmental Disclosure:
ENVPEP2206033EN
Device Application:
distribution
Quantity Per Set:
1
Network Frequency:
50/60 Hz
Ambient Air Temperature For Operation:
-25-70°C
Mounting Mode:
unit mount lug)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Name:
PowerPact P
Length:
25 mm
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Ambient Air Temperature For Storage:
-50-85°C
Pvc Free:
Yes
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green)
Circuit Breaker Application:
HACR rated
Electrical Connection:
lugs, line || lugs, load
Ip Degree Of Protection:
front cover IP40
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Line Rated Current:
600-600 A
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Warranty:
18 months
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Certifications:
UL || CSA || NOM
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Quality Labels:
CE
Eu Rohs Directive:
Compliant with Exemptions
Circularity Profile:
ENVEOLI2206033EN
Continuous Current Rating:
0.8
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Terminal Identifier:
AL800M23K
Wire Stripping Length:
25 mm
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Sustainable Offer Status:
Green Premium product
Net Weight:
32 lb(US)
$15,909.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose