Schneider Electric

Schneider Electric PJL36080CU63AE1 Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 25kA, lugs, Micrologic 5.0P, 100%, modbus

(No reviews yet) Write a Review
SKU:
PJL36080CU63AE1
MPN:
PJL36080CU63AE1
Condition:
New
Circularity Profile:
ENVEOLI2206033EN
Weight:
32 lb(US)
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Depth:
8.05 in
Wire Stripping Length:
25 mm
Length:
25 mm
Breaking Capacity Code:
J
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Circuit Breaker Application:
HACR rated
Device Application:
distribution
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Communication Interface:
Modbus
Mercury Free:
Yes
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Network Frequency:
50/60 Hz
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Mounting Mode:
unit mount lug)
Electrical Connection:
lugs, line || lugs, load
Warranty:
18 months
Product Or Component Type:
circuit breaker
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Ambient Air Temperature For Storage:
-50-85°C
Trip Unit Technology:
electronic, power, MicroLogic 5.0 P, LSI
Poles Description:
3P
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Product Certifications:
UL || CSA || NOM
Continuous Current Rating:
1
Product Name:
PowerPact P
Quality Labels:
CE
Terminal Identifier:
AL800M23K
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Net Weight:
32 lb(US)
Ambient Air Temperature For Operation:
-25-70°C
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Sustainable Offer Status:
Green Premium product
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Eu Rohs Directive:
Compliant with Exemptions
Control Type:
toggle
Mounting Support:
lug
Rohs Exemption Information:
Yes
Quantity Per Set:
1
Pvc Free:
Yes
Country of Origin:
Italy
$29,252.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Power with a 5.0P trip unit and an LSI function with Modbus communications. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose