Schneider Electric

Schneider Electric PJL36080U63AE1 Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 18kA, lugs, Micrologic 5.0P, 80%, modbus

(No reviews yet) Write a Review
SKU:
PJL36080U63AE1
MPN:
PJL36080U63AE1
Condition:
New
Mercury Free:
Yes
Pollution Degree:
3 IEC 60947-1
Net Weight:
32 lb(US)
Length:
25 mm
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Ip Degree Of Protection:
front cover IP40
Quality Labels:
CE
Trip Unit Technology:
electronic, power, MicroLogic 5.0 P, LSI
Electrical Connection:
lugs, line || lugs, load
Network Frequency:
50/60 Hz
Product Name:
PowerPact P
Mounting Mode:
unit mount lug)
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Range:
PowerPact
Wire Stripping Length:
25 mm
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Device Application:
distribution
Ambient Air Temperature For Storage:
-50-85°C
Eu Rohs Directive:
Compliant with Exemptions
Country of Origin:
United States
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Mounting Support:
lug
Trip Unit Name:
MicroLogic 5.0 P
Depth:
8.05 in
Warranty:
18 months
Environmental Disclosure:
ENVPEP2206033EN
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Continuous Current Rating:
0.8
Circularity Profile:
ENVEOLI2206033EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Product Certifications:
UL || CSA || NOM
Breaking Capacity Code:
J
Accessory / Separate Part Type:
Modbus connecting cable
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Sustainable Offer Status:
Green Premium product
Line Rated Current:
800-800 A
Quantity Per Set:
1
Poles Description:
3P
Pvc Free:
Yes
Local Signaling:
overload 1 1 LED amber) || 1 flag green) || trip causes 4 trip indicator red)
Product Or Component Type:
circuit breaker
Communication Interface:
Modbus
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
$22,332.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Power with a 5.0P trip unit and an LSI function with Modbus communications. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose