Schneider Electric

Schneider Electric PKA36060 Circuit breaker, PowerPacT P, 600A, 3 pole, 600VAC, 100kA, I-Line, ET1.0l, 80%, ABC

(No reviews yet) Write a Review
SKU:
PKA36060
MPN:
PKA36060
Condition:
New
Control Type:
toggle
Product Name:
PowerPact P
Mercury Free:
Yes
Net Weight:
32 lb(US)
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Length:
25 mm
Network Frequency:
50/60 Hz
Product Certifications:
UL || CSA || NOM
Breaking Capacity Code:
K
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Continuous Current Rating:
0.8
Device Application:
distribution
Circuit Breaker Application:
HACR rated
Trip Unit Name:
ET 1.0I
Ambient Air Temperature For Operation:
-25-70°C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mounting Support:
bracket
Range:
PowerPact
Electrical Connection:
I-Line connection, line || lugs, load
Warranty:
18 months
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Phase Connection:
ABC
Mounting Mode:
I-Line bracket)
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Pvc Free:
Yes
Line Rated Current:
600-600 A
Depth:
8.05 in
Terminal Identifier:
AL800M23K
Circularity Profile:
ENVEOLI1407012EN
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Product Or Component Type:
circuit breaker
Country of Origin:
United States
Environmental Disclosure:
ENVPEP1407012EN
Poles Description:
3P
Quantity Per Set:
1
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 50 kA 480 V AC 50/60 Hz UL 489 || AIR 50 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Weight:
32 lb(US)
Ambient Air Temperature For Storage:
-50-85°C
Pollution Degree:
3 IEC 60947-1
Quality Labels:
CE
Mounting Height:
9 in
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Wire Stripping Length:
25 mm
Trip Unit Technology:
electronic, basic, ET 1.0I, I
Utilisation Category:
category A
Eu Rohs Directive:
Compliant
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
$23,220.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose