Schneider Electric

Schneider Electric PKL36120CU33A Circuit breaker, PowerPacT P, 1200A, 3 pole, 600VAC, 65kA, lugs, Micrologic 5.0, 100%

(No reviews yet) Write a Review
SKU:
PKL36120CU33A
MPN:
PKL36120CU33A
Condition:
New
Control Type:
toggle
Length:
30 mm
Device Application:
distribution
Quality Labels:
CE
Circuit Breaker Application:
HACR rated
Country of Origin:
United States
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Terminal Identifier:
AL1200P25K
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Mounting Support:
lug
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Circularity Profile:
ENVEOLI2206033EN
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Range:
PowerPact
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Suitability For Isolation:
yes IEC 60947-2
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Ambient Air Temperature For Operation:
-25-70°C
Ip Degree Of Protection:
front cover IP40
Pollution Degree:
3 IEC 60947-1
Network Frequency:
50/60 Hz
Poles Description:
3P
Utilisation Category:
category A
Breaking Capacity Code:
K
Eu Rohs Directive:
Compliant with Exemptions
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Sustainable Offer Status:
Green Premium product
Mounting Mode:
unit mount lug)
Wire Stripping Length:
30 mm
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Continuous Current Rating:
1
Depth:
8.05 in
Line Rated Current:
1200-1200 A
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green)
Product Name:
PowerPact P
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Environmental Disclosure:
ENVPEP2206033EN
Quantity Per Set:
1
Mercury Free:
Yes
Net Weight:
32 lb(US)
Product Certifications:
UL || CSA || NOM
Trip Unit Name:
MicroLogic 5.0
$32,466.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.