Operating Altitude:
0...6561.68 ft (0...2000 m) without derating
Height:
116 mm
Mechanical Durability:
30 Mcycles
[Uc] Control Circuit Voltage:
24 V DC supplied by the bus coupler
Utilisation Category:
AC-1 || AC-2 || AC-3 || AC-4 || AC-3e
[Ith] Conventional Free Air Thermal Current:
15 A (at 50°C)
Circularity Profile:
ENVEOLI1904009EN
Power Dissipation In W:
3.5 W at Ie AC-3
Motor Power Kw:
2.2 kW at 230 V 50 Hz (AC-3) || 4 kW at 380...415 V 50 Hz (AC-3) || 4 kW at 440 V 50 Hz (AC-3) || 5.5 kW at 500 V 50 Hz (AC-3) || 5.5 kW at 690 V 50 Hz (AC-3)
Device Presentation:
direct starter connected to an automation controller through a bus coupler || operational only when connected to a bus coupler
Poles Description:
3P 3 NO
Ip Degree Of Protection:
IP20
[Ie] Rated Operational Current:
9 A (at <50°C) at <= 440 V AC-3 || 15 A (at <50°C) at <= 440 V AC-1
Sustainable Offer Status:
Green Premium product
Function Available:
upstream voltage presence detection || electrical line and load protection || power and energy monitoring when connected with TPRVM voltage module
Electrical Durability:
2 Mcycles 9 A AC-3 440 V || 1.2 Mcycles 15 A AC-1 440 V
Motor Starter Type:
direct on line
Relative Humidity:
5-95 %
Environmental Disclosure:
ENVPEP1904009EN
Width:
45 mm
Ambient Air Temperature For Operation:
-10-50°C without derating || 50-60°C with current derating
Halogen Content Performance:
Halogen free plastic parts product
Average Impedance:
2.5 mOhm - Ith 15 A 50 Hz
Weight:
0.656 kg
[Ui] Rated Insulation Voltage:
690 V IEC 60947-4-1 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Overvoltage Category:
III
Local Signaling:
for DS (device status) 1 LED (green/red) || for LS (load status) 1 LED (green/red)
Mounting Mode:
horizontal and vertical 35 mm symmetrical DIN rail)
[Ue] Rated Operational Voltage:
<= 690 V AC 47...63 Hz
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-1
Warranty:
18 months
Product Or Component Type:
motor starter
Rated Breaking Capacity:
250 A at 440 V conforming to IEC 60947
Net Weight:
0.656 kg
Reset:
remotely or automatically
Ambient Air Temperature For Storage:
-25-70°C
Metering Type:
time device ON || time device switch ON || number of faults || number of switching cycles || number of device power cycles || average current Iavg || average voltage Vavg || max current Imax || max voltage Vmax || active and reactive power with volta
Thermal Overload Class:
class 5…30
Country of Origin:
United States
Protection Type:
thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase sequence || rapid restart lockout || phase reversal || phase loss || phase unbalance || ground current
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Operating Time:
< 100 ms closing || < 30 ms opening
Product Name:
TeSys island
Product Certifications:
EAC || CSA || CCC || UL
Power Dissipation Per Pole:
0.2 W AC-3 - Ith 9 A || 0.56 W AC-1 - Ith 15 A
Electromagnetic Compatibility:
electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transient immunity test, level 4, 4 kV, conforming to E
Pollution Degree:
2
Mercury Free:
Yes
Current Consumption:
160 mA contactor sealed || 160 mA contactor closing
Device Short Name:
TPRST
$225.00

Description

TeSys island direct starter, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).