Schneider Electric TPRST038 Motor starter, TeSys island, 40A at AC-1, 38A at AC-3, 18.5kW, 20hp, DOL type
Schneider Electric
$395.00
TeSys island direct starter, 3 poles, 38A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 38A and motors up to 18,5kW@400V / 20hp@480V. It provides motor protection functions including thermal overload (setting 0.76-38A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
- Thermal Protection Adjustment Range:
- 0.76-38 A
- Rohs Exemption Information:
- Yes
- Irms Rated Making Capacity:
- 550 A at 440 V conforming to IEC 60947
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Weight:
- 0.718 kg
- [Ue] Rated Operational Voltage:
- <= 480 V AC 47...63 Hz for overvoltage cat. III || <= 690 V AC 47...63 Hz for overvoltage cat. II
- Standards:
- EN/IEC 60947-1 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
- Width:
- 45 mm
- Vibration Resistance:
- 1.5 mm peak to peak 3-13 Hz) IEC 60068-2-6 || 1 gn 13-200 Hz) IEC 60068-2-6
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-1
- Device Presentation:
- direct starter connected to an automation controller through a bus coupler || operational only when connected to a bus coupler
- Rated Breaking Capacity:
- 550 A at 440 V conforming to IEC 60947
- Protective Treatment:
- TC
- Thermal Overload Class:
- class 5…30
- Reset:
- remotely or automatically
- Device Short Name:
- TPRST
- [Ui] Rated Insulation Voltage:
- 690 V IEC 60947-4-1 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
- Ambient Air Temperature For Operation:
- -10-50°C without derating || 50-60°C with current derating
- Power Dissipation Per Pole:
- 2.9 W AC-3 - Ith 38 A || 3.2 W AC-1 - Ith 40 A
- Maximum Horse Power Rating:
- 2 hp at 120 V AC 60 Hz for 1 phase motors || 5 hp at 240 V AC 60 Hz for 1 phase motors || 10 hp at 208 V AC 60 Hz for 3 phase motors || 10 hp at 240 V AC 60 Hz for 3 phase motors || 20 hp at 480 V AC 60 Hz for 3 phase motors || 25 hp at 600 V AC 60 H
- Utilisation Category:
- AC-1 || AC-2 || AC-3 || AC-4 || AC-3e
- Operating Time:
- < 100 ms closing || < 30 ms opening
- Circularity Profile:
- ENVEOLI1904009EN
- Product Compatibility:
- TPRBC bus coupler || TPRVM voltage interface module
- Mechanical Durability:
- 30 Mcycles
- Eu Rohs Directive:
- Compliant with Exemptions
- Pollution Degree:
- 2
- Net Weight:
- 0.718 kg
- Sustainable Offer Status:
- Green Premium product
- Warranty:
- 18 months
- Fire Resistance:
- 960°C UL 94 || 850°C IEC 60695-2-1 || 650°C IEC 60695-2-12
- Operating Altitude:
- 0...6561.68 ft (0...2000 m) without derating
- Current Consumption:
- 160 mA contactor sealed || 160 mA contactor closing
- Electrical Durability:
- 1.4 Mcycles 38 A AC-3 440 V || 2 Mcycles 40 A AC-1 440 V
- Electromagnetic Compatibility:
- electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transient immunity test, level 4, 4 kV, conforming to E
- Ip Degree Of Protection:
- IP20
- Overvoltage Category:
- III for Ue <= 480 V || II for Ue <= 690 V
- Country of Origin:
- France
- Maximum Operating Rate:
- 3600 cyc/mn AC-3
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Tightening Torque:
- 2.5-2.5 N.m flat Ø 6 mm || 2.5-2.5 N.m Philips No 3
- Protection Type:
- thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase sequence || rapid restart lockout || phase loss || phase reversal || phase unbalance || ground current
- Relative Humidity:
- 5-95 %
- [Ith] Conventional Free Air Thermal Current:
- 40 A (at 50°C)
- Product Certifications:
- CCC || EAC || UL || CSA
- [Ie] Rated Operational Current:
- 38 A (at <50°C) at <= 440 V AC-3 || 40 A (at <50°C) at <= 440 V AC-1
- Mounting Mode:
- horizontal and vertical 35 mm symmetrical DIN rail)
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.