Schneider Electric

Schneider Electric TPRST065 Motor starter, TeSys island, 80A at AC-1, 65A at AC-3, 30kW, 40hp, DOL type

(No reviews yet) Write a Review
SKU:
TPRST065
MPN:
TPRST065
Condition:
New
Product Certifications:
CSA || UL || EAC || CCC
Thermal Overload Class:
class 5…30
Environmental Disclosure:
ENVPEP1904009EN
Power Dissipation In W:
20.8 W at Ie AC-3
Electrical Durability:
1.4 Mcycles 65 A AC-3 440 V || 0.5 Mcycles 80 A AC-1 440 V
Rohs Exemption Information:
Yes
Metering Type:
time device ON || time device switch ON || number of faults || number of switching cycles || number of device power cycles || average current Iavg || average voltage Vavg || max current Imax || max voltage Vmax || active and reactive power with volta
Protection Type:
thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase sequence || rapid restart lockout || phase reversal || phase loss || phase unbalance || ground current
[Icw] Rated Short-Time Withstand Current:
900 A 40°C - 1 s || 520 A 40°C - 10 s || 260 A 40°C - 1 min || 110 A 40°C - 10 min
Maximum Operating Rate:
3600 cyc/mn AC-3
Mounting Mode:
horizontal and vertical 35 mm symmetrical DIN rail)
[Uc] Control Circuit Voltage:
24 V DC supplied by the bus coupler
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Operation:
-10-50°C without derating || 50-60°C with current derating
Vibration Resistance:
1.5 mm peak to peak 3-13 Hz) IEC 60068-2-6 || 1 gn 13-200 Hz) IEC 60068-2-6
Motor Starter Type:
direct on line
Net Weight:
1.248 kg
Protective Treatment:
TC
[Ui] Rated Insulation Voltage:
690 V IEC 60947-4-1 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
[Ie] Rated Operational Current:
65 A (at <50°C) at <= 440 V AC-3 || 80 A (at <50°C) at <= 440 V AC-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Irms Rated Making Capacity:
1000 A at 440 V conforming to IEC 60947
[Ue] Rated Operational Voltage:
<= 690 V AC 47...63 Hz
Mechanical Durability:
6 Mcycles
Shock Resistance:
15 gn 11 ms) IEC 60068-2-27
Utilisation Category:
AC-1 || AC-2 || AC-3 || AC-4 || AC-3e
Eu Rohs Directive:
Compliant with Exemptions
Relative Humidity:
5-95 %
Fire Resistance:
960°C UL 94 || 850°C IEC 60695-2-1 || 650°C IEC 60695-2-12
Ambient Air Temperature For Storage:
-25-70°C
Width:
55 mm
Country of Origin:
France
Circularity Profile:
ENVEOLI1904009EN
Product Name:
TeSys island
Halogen Content Performance:
Halogen free plastic parts product
Device Presentation:
direct starter connected to an automation controller through a bus coupler || operational only when connected to a bus coupler
Range:
TeSys
Depth:
125 mm
Maximum Horse Power Rating:
5 hp at 120 V AC 60 Hz for 1 phase motors || 10 hp at 240 V AC 60 Hz for 1 phase motors || 20 hp at 208 V AC 60 Hz for 3 phase motors || 20 hp at 240 V AC 60 Hz for 3 phase motors || 40 hp at 480 V AC 60 Hz for 3 phase motors || 50 hp at 600 V AC 60
Local Signaling:
for DS (device status) 1 LED (green/red) || for LS (load status) 1 LED (green/red)
Product Or Component Type:
motor starter
Motor Power Kw:
18.5 kW at 230 V 50 Hz (AC-3) || 30 kW at 380...415 V 50 Hz (AC-3) || 30 kW at 440 V 50 Hz (AC-3) || 37 kW at 500 V 50 Hz (AC-3) || 37 kW at 690 V 50 Hz (AC-3)
Warranty:
18 months
Device Short Name:
TPRST
Poles Description:
3P 3 NO
Ip Degree Of Protection:
IP20
Mercury Free:
Yes
Operating Altitude:
0...6561.68 ft (0...2000 m) without derating
$635.00

Description

TeSys island direct starter, 3 poles, 65A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 65A and motors up to 30kW@400V / 40hp@480V. It provides motor protection functions including thermal overload (setting 3.35-65A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose