Schneider Electric

Schneider Electric VLS3P016D1 Disconnect switch, TeSys VLS, body switch, 16A, 10HP at 480VAC, UL508, three phase, 5kA SCCR, size 1, door mount

(No reviews yet) Write a Review
SKU:
VLS3P016D1
MPN:
VLS3P016D1
Condition:
New
Performance Level:
high performance
Eu Rohs Directive:
Compliant
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Rohs Exemption Information:
Yes
Intermittent Duty Class:
class 120 - 60 %
Country of Origin:
Italy
Reach Free Of Svhc:
Yes
Contacts Type And Composition:
3 NO
Poles Description:
3P
Electrical Durability:
100000 cycles AC-21A
[Icw] Rated Short-Time Withstand Current:
800 A 690 V 1 s
Rated Conditional Short-Circuit Current:
50 kA 400 V 16 A gG
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Weight:
0.135 kg
Connections - Terminals:
power circuit screw clamp terminals 10-10 mm² solid || power circuit screw clamp terminals 16-16 mm² flexible - without cable end
Mechanical Durability:
100000 cycles
Product Certifications:
cULus || GL
Depth:
73 mm
Mercury Free:
Yes
Color:
Gray
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Icm] Rated Short-Circuit Making Capacity:
1128 A 690 V
Ambient Air Temperature For Operation:
-25-55°C
Rated Operational Power In W:
7.5 kW 400 V AC-23A) || 7.5 kW 500 V AC-23A) || 11 kW 690 V AC-23A)
Product Name:
TeSys VARIO LS
Network Frequency:
50/60 Hz
Device Short Name:
VLS3P
Toxic Heavy Metal Free:
Yes
Tightening Torque:
power circuit 1.8-2 N.m screw clamp terminals
Product Or Component Type:
switch body
[Ithe] Conventional Enclosed Thermal Current:
16 A
Fire Resistance:
960°C IEC 60695-2-11
Making Capacity:
24 A 690 V AC-21A || 48 A 690 V AC-22A || 160 A 690 V AC-23A
[Ie] Rated Operational Current:
16 A Ue: 600 V UL 508 || 16 A AC-21A Ue: 400 V || 16 A AC-21A Ue: 500 V || 16 A AC-21A Ue: 690 V || 16 A AC-22A Ue: 400 V || 16 A AC-22A Ue: 500 V || 16 A AC-22A Ue: 690 V || 16 A AC-23A Ue: 400 V || 16 A AC-23A Ue: 500 V || 16 A AC-23A Ue: 690 V
Standards:
UL 508 || CSA C22.2 No 14 || IEC 60947-3
Mechanical Robustness:
vibrations 2...100 Hz Fc 0.7 g) IEC 60068-2-6 || shocks 11 ms Ea 15 gn) IEC 60068-2-27
Mounting Support:
door
[Ith] Conventional Free Air Thermal Current:
16 A (at 55°C)
Network Type:
AC
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 508
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Net Weight:
0.135 kg
Breaking Capacity:
24 A 690 V AC-21A) || 48 A 690 V AC-22A) || 128 A 690 V AC-23A)
Range:
TeSys
$45.36

Description

These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This 16A disconnect switch has 3 normally open poles and mounts directly in the enclosure door. Per UL and CSA this this disconnect switch has a 1 HP rating at 120 VAC and a 2 HP at 240 VAC single phase. Per UL and CSA this disconnect switch has a 5 HP rating at 200 to 208 VAC and 240 VAC and a 10 HP rating at 480 and 600 VAC three phase. Per UL508A this this disconnect switch has up to a 5 kA at 600 V short circuit current rating (SCCR) with a 30A Type RK5 fuse maximum. Per IEC requirements, this disconnect switch has a 7.5 kW rating at 400 and 500 V and a 11 kW rating at 690V three phase. The screw clamp terminals will accept 10 mm solid or 16 mm stranded wire. The clamps will also accept solid or stranded wire from 18 AWG to 6 AWG. This disconnect switch is 3.07 inches tall, 1.77 inches wide and 2.87 inches deep. The switch weighs 0.30 lbs. There are many handles and accessories available this TeSys VLS disconnect switch. This TeSys VLS disconnect switch is UL Listed per UL60947-4-1, CSA certified per CSA 22.2 and meets IEC 60947-3 requirements.
View AllClose