Schneider Electric DPE50U7 IEC contactor,Easy TeSys DPE,nonreversing,50A,3P,30HP at 480V AC,240V AC 50/60Hz coil
Schneider Electric
$95.00
Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 50A/690V AC-3 (30HP@480V). It provides a 240 VAC coil, 1NO built-in auxiliary contacts, connection by screw clamp terminals. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).
- Circularity Profile:
- ENVEOLI1503009EN
- Eu Rohs Directive:
- Compliant
- Heat Dissipation:
- 4-5 W 50/60 Hz
- Ambient Air Temperature For Storage:
- -60-80°C
- Environmental Disclosure:
- ENVPEP1503009EN
- Pole Contact Composition:
- 3 NO
- Pollution Degree:
- 3
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C)
- Control Circuit Type:
- AC 50/60 Hz
- Depth:
- 122 mm
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Range:
- Easy TeSys
- Power Dissipation Per Pole:
- 3.7 W AC-3 || 9.6 W AC-1
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V cUL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V cUL
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
- Operating Altitude:
- 0...6561.68 ft (0...2000 m)
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Reach Free Of Svhc:
- Yes
- Poles Description:
- 3P
- Auxiliary Contact Composition:
- 1 NO
- Product Or Component Type:
- contactor
- [Icw] Rated Short-Time Withstand Current:
- 400 A 40°C - 10 s for power circuit || 810 A 40°C - 1 s for power circuit || 84 A 40°C - 10 min for power circuit || 208 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Motor Power Kw:
- 15 kW 220...230 V AC 50/60 Hz || 22 kW 380...400 V AC 50/60 Hz || 25 kW 415 V AC 50/60 Hz || 30 kW 440 V AC 50/60 Hz || 30 kW 500 V AC 50/60 Hz || 33 kW 660...690 V AC 50/60 Hz
- Overvoltage Category:
- III
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3 for power circuit
- Mercury Free:
- Yes
- Fire Resistance:
- 850°C IEC 60695-2-1
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Signaling Circuit Frequency:
- 25...400 Hz
- Product Name:
- Easy TeSys DPE
- Maximum Horse Power Rating:
- 3 hp at 115 V AC 50/60 Hz for 1 phase motors || 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 30 hp at 460/480 V AC 50/60 Hz for 3 phase m
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Coil Technology:
- without built-in suppressor module
- Device Short Name:
- DPE
- Mechanical Durability:
- 5 Mcycles
- Product Certifications:
- cULus
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- [Uc] Control Circuit Voltage:
- 240 V AC 50/60 Hz
- Control Circuit Voltage Limits:
- drop-out: 0.3...0.6 Uc at 50/60 Hz (at <70°C) || operational: 0.8...1.1 Uc at 50 Hz (at <60°C) || operational: 0.85...1.1 Uc at 60 Hz (at <60°C) || operational: 1...1.1 Uc at 50/60 Hz (at <70°C)
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Ambient Air Temperature For Operation:
- -40-60°C
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit