Schneider Electric

Schneider Electric HGL36150U53X Circuit breaker, PowerPacT H, 150A, 3 pole, 600VAC, 18kA, lugs, Micrologic 5.2E, 80%

(No reviews yet) Write a Review
SKU:
HGL36150U53X
MPN:
HGL36150U53X
Condition:
New
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Color:
Black
Poles Description:
3P
Suitability For Isolation:
yes IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Mounting Support:
lug
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Utilisation Category:
category A
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Network Frequency:
50/60 Hz
Device Application:
distribution
Quantity Per Set:
1
Length:
16 mm
Wire Stripping Length:
16 mm
Ambient Air Temperature For Operation:
-25-70°C
Pvc Free:
Yes
Circuit Breaker Application:
HACR rated
Terminal Identifier:
AL150HD
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Ip Degree Of Protection:
front cover IP40 IEC 60529
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Sustainable Offer Status:
Green Premium product
Protected Poles Description:
3t
Product Name:
PowerPact H
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Range:
PowerPact
Weight:
2.2 kg
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ambient Air Temperature For Storage:
-50-85°C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mounting Mode:
unit mount lug)
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Quality Labels:
CE
Trip Unit Name:
MicroLogic 5.2 E
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Rohs Exemption Information:
Yes
Electrical Connection:
lugs, line || lugs, load
Circularity Profile:
ENVEOLI2206028EN
Control Type:
toggle
Country of Origin:
United States
Product Or Component Type:
circuit breaker
Product Certifications:
UL || CSA || NOM
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
$4,902.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Energy with a 5.2E trip unit and an LSI function with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 150A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.