Schneider Electric

Schneider Electric LC1D50A6BNE IEC contactor, TeSys Deca Green, nonreversing, 50A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 24/60VAC/VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D50A6BNE
MPN:
LC1D50A6BNE
Condition:
New
Fire Resistance:
850°C IEC 60695-2-1
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
Mechanical Durability:
6 Mcycles
Irms Rated Making Capacity:
900 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Ip Degree Of Protection:
IP20 front face IEC 60529
Protective Cover:
with
Electrical Durability:
1.8 Mcycles 42 A AC-3 <= 440 V || 0.5 Mcycles 80 A AC-1 <= 440 V || 1.8 Mcycles 42 A AC-3e <= 440 V
Eu Rohs Directive:
Compliant with Exemptions
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Minimum Switching Voltage:
17 V for Signaling circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Operating Altitude:
0...9842.52 ft (0...3000 m)
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Heat Dissipation:
0.7-0.7 W at 50/60 Hz
Contactor Application:
resistive load || motor control
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Operating Time:
55...65 ms closing || 20...80 ms opening
Sustainable Offer Status:
Green Premium product
Rohs Exemption Information:
Yes
Product Or Component Type:
contactor
Auxiliary Contact Composition:
1 NO + 1 NC
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Device Short Name:
LC1D
Depth:
120 mm
Weight:
0.997 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Maximum Operating Rate:
3600 cyc/h 60°C
Flame Retardance:
V1 conforming to UL 94
Coil Technology:
built-in bidirectional peak limiting
Hold-In Power Consumption In Va:
1-1 VA 50/60 Hz (at 20°C)
Range:
TeSys || TeSys Deca
Utilisation Category:
AC-1 || AC-3 || AC-3e
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Circularity Profile:
ENVEOLI1607010EN
Height:
122 mm
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
[Icw] Rated Short-Time Withstand Current:
84 A 40°C - 10 min for power circuit || 208 A 40°C - 1 min for power circuit || 400 A 40°C - 10 s for power circuit || 810 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Motor Power Kw:
15 kW at 220...230 V AC 50 Hz (AC-3) || 22 kW at 380...400 V AC 50 Hz (AC-3) || 25 kW at 415 V AC 50 Hz (AC-3) || 30 kW at 440 V AC 50 Hz (AC-3) || 30 kW at 500 V AC 50 Hz (AC-3) || 33 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 220...230 V AC 50 H
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Power Dissipation Per Pole:
9.6 W AC-1 || 3.7 W AC-3 || 3.7 W AC-3e
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4 |
Overvoltage Category:
III
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors || 15 hp at 200/208 V AC 60 Hz for 3 phase motors || 15 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 40 h
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mercury Free:
Yes
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
$367.20

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.20 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose