Schneider Electric

Schneider Electric LC1D65E7 IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D65E7
MPN:
LC1D65E7
Condition:
New
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mounting Support:
rail
Depth:
176 mm
Range:
TeSys
Utilisation Category:
AC-2 || AC-1 || AC-3 || AC-3e
Protective Cover:
with
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Connections - Terminals:
control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cab
Mechanical Durability:
10000000 cycles
Ip Degree Of Protection:
IP2X VDE 0106 || IP2X IEC 60529
Circularity Profile:
N/A
Reach Free Of Svhc:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Device Short Name:
LC1D
Maximum Operating Rate:
3600 cyc/h 60°C
Rohs Exemption Information:
Yes
Fire Resistance:
850°C IEC 60695-2-1
Net Weight:
2.185 kg
Auxiliary Contacts Type:
mirror contact 1 NC IEC 60947-4-1 || mechanically linked 1 NO + 1 NC IEC 60947-5-1
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Ith] Conventional Free Air Thermal Current:
80 A (at 60°C) for power circuit || 10 A (at 60°C) for control circuit
Inrush Power In Va:
160-160 VA cos phi 0.75 (at 20°C)
Climatic Withstand:
IACS E10 exposure to damp heat
Product Or Component Type:
contactor
Overvoltage Category:
III
Minimum Switching Current:
5 mA for control circuit
Country of Origin:
Czechia
Toxic Heavy Metal Free:
Yes
Motor Power Kw:
11 kW at 400 V AC 50 Hz (AC-4) || 30 kW at 380...400 V AC 50 Hz (AC-3) || 37 kW at 500 V AC 50 Hz (AC-3) || 37 kW at 660...690 V AC 50 Hz (AC-3) || 18.5 kW at 220...230 V AC 50 Hz (AC-3) || 30 kW at 415 V AC 50 Hz (AC-3) || 37 kW at 1000 V AC 50 Hz (
Sustainable Offer Status:
Green Premium product
Standards:
IEC 60947-4-1 || IEC 60947-5-1 || EN 60947-4-1 || CSA C22.2 No 14 || UL 508
Non-Overlap Time:
1.5 ms on energisation between NC and NO contacts || 1.5 ms on de-energisation between NC and NO contacts
Minimum Switching Voltage:
17 V for control circuit
Product Certifications:
GOST || CCC || UL || DNV || RINA || LROS (Lloyds register of shipping) || BV || GL || UKCA
Contactor Application:
motor control
Operating Time:
12...26 ms closing || 50 ms closing || 20 ms opening
Control Circuit Type:
DC standard
Auxiliary Contact Composition:
1 NO + 1 NC
Flame Retardance:
V1 conforming to UL 94
Insulation Resistance:
> 10 MOhm for control circuit
Eu Rohs Directive:
Compliant
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
[Ie] Rated Operational Current:
65 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Range Of Product:
TeSys Deca
Weight:
2.185 kg
Rated Operational Power In W:
12 W 48 V DC-13 10000000 cycles - control circuit || 38 W 48 V DC-13 3000000 cycles - control circuit
Control Circuit Voltage Limits:
0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz || 0.75...1.25 Uc -40-60°C operational DC || 0.1...0.3 Uc -40-70°C drop-out DC
[Uc] Control Circuit Voltage:
48 V DC
$532.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 48 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose