Schneider Electric

Schneider Electric LC1D80ABNE IEC contactor, TeSys Deca Green, nonreversing, 80A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 24/60VAC/VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D80ABNE
MPN:
LC1D80ABNE
Condition:
New
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC || 0.8...1.1 Uc -40-60°C operational DC || 1...1.1 Uc 60-70°C operational AC/DC
Range:
TeSys || TeSys Deca
Halogen Content Performance:
Halogen free plastic parts & cables product
Minimum Switching Voltage:
17 V for Signaling circuit
Power Dissipation Per Pole:
9.6 W AC-1 || 6.3 W AC-3 || 6.3 W AC-3e
Pole Contact Composition:
3 NO
Sustainable Offer Status:
Green Premium product
Motor Power Kw:
22 kW at 220...230 V AC 50/60 Hz (AC-3) || 37 kW at 380...400 V AC 50/60 Hz (AC-3) || 37 kW at 415 V AC 50/60 Hz (AC-3) || 37 kW at 440 V AC 50/60 Hz (AC-3) || 37 kW at 500 V AC 50/60 Hz (AC-3) || 37 kW at 660...690 V AC 50/60 Hz (AC-3) || 22 kW at 2
Depth:
120 mm
Circularity Profile:
ENVEOLI1607010EN
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC-1 for power circuit || 66 A (at <60°C) at <= 440 V AC-3 for power circuit || 66 A (at <60°C) at <= 440 V AC-3e for power circuit
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Mechanical Durability:
6 Mcycles
Hold-In Power Consumption In Va:
1-1 VA 50/60 Hz (at 20°C)
Warranty:
18 months
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Poles Description:
3P
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
Ip Degree Of Protection:
IP20 front face IEC 60529
Hold-In Power Consumption In W:
0.7-0.7 W 20°C
Protective Cover:
with
Mercury Free:
Yes
Associated Fuse Rating:
125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Maximum Operating Rate:
3600 cyc/h 60°C
Eu Rohs Directive:
Compliant with Exemptions
Utilisation Category:
AC-3 || AC-1 || AC-3e
Inrush Power In Va:
15-15 VA 50/60 Hz (at 20°C)
Operating Altitude:
0...9842.52 ft (0...3000 m)
Weight:
1.002 kg
Auxiliary Contact Composition:
1 NO + 1 NC
Compatibility Code:
LC1D
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Operating Time:
55...65 ms closing || 20...80 ms opening
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Environmental Disclosure:
ENVPEP1607010EN
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Overvoltage Category:
III
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V AC for power circuit conforming to IEC 60947
Flame Retardance:
V1 conforming to UL 94
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
$444.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 40HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.