Schneider Electric

Schneider Electric LC2D50G7 Reversing Contactor, TeSys Deca, 3P(3NO), AC-3, IEC, <=440V, 50A, 120V AC 60Hz coil

(No reviews yet) Write a Review
SKU:
LC2D50G7
MPN:
LC2D50G7
Condition:
New
Fire Resistance:
850°C IEC 60695-2-1
Pole Contact Composition:
3 NO
Minimum Switching Voltage:
17 V for control circuit
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Minimum Switching Current:
5 mA for control circuit
Reach Free Of Svhc:
Yes
Standards:
IEC 60947-4-1 || CSA C22.2 No 14 || UL 508 || IEC 60947-5-1 || EN 60947-4-1 || EN 60947-5-1
Connections - Terminals:
control circuit 1 1-4 mm²flexible with cable end || power circuit 2 1-25 mm²flexible with cable end || power circuit 2 1-25 mm²flexible without cable end || power circuit 2 1-25 mm²solid without cable end || power circuit 2 1-35 mm²flexible with
Overvoltage Category:
III
Interlocking Type:
mechanical
Product Or Component Type:
reversing contactor
Device Short Name:
LC2D
Sustainable Offer Status:
Green Premium product
Control Circuit Voltage Limits:
drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60°C) || operational: 0.8...1.1 Uc at 50 Hz (at <60°C) || operational: 0.85...1.1 Uc at 60 Hz (at <60°C)
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Range Of Product:
TeSys Deca
Mercury Free:
Yes
Insulation Resistance:
> 10 MOhm for control circuit
Ambient Air Temperature For Storage:
-60-80°C
Circularity Profile:
N/A
Warranty:
18 months
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Protective Treatment:
TH 3)IEC 60068
Maximum Operating Rate:
3600 cyc/h 60°C
Control Circuit Type:
AC
Coil Type:
standard
Product Certifications:
GL || UL || RINA || GOST || CSA || LROS (Lloyds register of shipping) || CCC || DNV || BV || UKCA
Flame Retardance:
V1 conforming to UL 94
Environmental Disclosure:
ENVPEP110205EN
Net Weight:
2.4 kg
Height:
132 mm
Vibration Resistance:
2 gn 5-300 Hz contactor opened || 3 gn 5-300 Hz contactor closed
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Heat Dissipation:
6-10 W at 50/60 Hz for control circuit
Toxic Heavy Metal Free:
Yes
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Hold-In Power Consumption In Va:
20-20 VA 50 Hz cos phi 0.3 (at 20°C) || 22-22 VA 60 Hz cos phi 0.3 (at 20°C) || 26-26 VA 50 Hz cos phi 0.3 (at 20°C) || 26-26 VA 60 Hz cos phi 0.3 (at 20°C)
Mechanical Durability:
6000000 cycles
Protective Cover:
with
Weight:
2.4 kg
[Ui] Rated Insulation Voltage:
control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
Motor Power Kw:
15 kW 220...240 V AC 50/60 Hz || 22 kW 380...400 V AC 50/60 Hz || 25 kW 415 V AC 50/60 Hz || 30 kW 440 V AC 50/60 Hz || 30 kW 500 V AC 50/60 Hz || 33 kW 660...690 V AC 50/60 Hz
Mounting Support:
plate || rail
Shock Resistance:
10 gn contactor closed || 8 gn contactor opened
Ambient Air Temperature For Operation:
-5-60°C
[Ue] Rated Operational Voltage:
power circuit <= 1000 V AC 25...400 Hz
Pvc Free:
Yes
Operating Time:
12...26 ms closing || 4...19 ms opening
$991.44