Schneider Electric

Schneider Electric BDF26080 Circuit breaker, PowerPacT B, 80A, 2 pole, 600Y/347VAC, 14kA, terminal nut, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
BDF26080
MPN:
BDF26080
Condition:
New
Continuous Current Rating:
0.8
Poles Description:
2P
Trip Unit Name:
TM-D
Sustainable Offer Status:
Green Premium product
Control Type:
toggle
Network Frequency:
50/60 Hz
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Quantity Per Set:
set of 1
Protected Poles Description:
2t
Pvc Free:
Yes
Quality Labels:
CE
Mounting Mode:
clip-on 35 mm symmetrical DIN rail) || by screws plate)
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Local Signaling:
presence of auxiliary contacts flag green)
Ip Degree Of Protection:
front cover IP40 IEC 60529
Ambient Air Temperature For Operation:
-25-70°C
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Electrical Connection:
terminal nut, ON and OFF end
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 18 kA 240 V AC 50/60 Hz UL 489 || Icu 25 kA 480/277 V AC 50/60 Hz UL 489 || Icu 14 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489 || 14 kA 250 V DC UL 489 || 25 kA || Icu 18 kA
Product Name:
PowerPact B
Height:
137 mm
Length:
20 mm
Country of Origin:
Mexico
Weight:
0.669 kg
Suitability For Isolation:
yes IEC 60947-2
9 Mm Pitches:
6
Connection Pitch:
27 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Trip Unit Technology:
thermal-magneticTM-D,
Color:
Gray RAL 7016)
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Operating Altitude:
6561.68 ft (2000 m) without derating || 5000 m with derating
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Wire Stripping Length:
20 mm
Awg Gauge:
AWG 14...AWG 8 aluminium/copper || AWG 6...AWG 3/0 aluminium/copper
Depth:
80 mm
Line Rated Current:
80-80 A
Mercury Free:
Yes
Eu Rohs Directive:
Compliant
Breaking Capacity Code:
D
Mechanical Durability:
15000 cycles IEC 947-1 Annex K ed 5.2
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Utilisation Category:
category A
Standards:
EN/IEC 60947-2 || NEMA AB1 || UL 489 || EN/IEC 60947-5-1 || NMX J-266 || GB 14048.2 || CSA C22.2 No 5
Net Weight:
0.669 kg
Environmental Disclosure:
ENVPEP1610005EN
$1,434.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit has terminal nuts on both termination ends. This PowerPacT B, 80A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.