Schneider Electric

Schneider Electric BJF36025 Circuit breaker, PowerPacT B, 25A, 3 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
BJF36025
MPN:
BJF36025
Condition:
New
Device Application:
distribution
Halogen Content Performance:
Halogen free product
Trip Unit Name:
TM-D
[Ics] Rated Service Breaking Capacity:
100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 2.5 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Poles Description:
3P
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Depth:
80 mm
Standards:
CSA C22.2 No 5 || NMX J-266 || UL 489 || GB 14048.2 || NEMA AB1 || EN/IEC 60947-5-1 || EN/IEC 60947-2
Network Frequency:
50/60 Hz
Circuit Breaker Application:
HACR rated
Weight:
0.924 kg
Wire Stripping Length:
20 mm
Ambient Air Temperature For Storage:
-50-85°C
Line Rated Current:
25-25 A
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
0.924 kg
Country of Origin:
United States
Product Or Component Type:
circuit breaker
Protected Poles Description:
3t
Pvc Free:
Yes
Trip Unit Technology:
thermal-magneticTM-D,
Circularity Profile:
N/A
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ip Degree Of Protection:
front cover IP40 IEC 60529
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz UL 489
Product Name:
PowerPact B
Length:
20 mm
Suitability For Isolation:
yes IEC 60947-2
Breaking Capacity:
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Utilisation Category:
category A
Electrical Connection:
terminal nut, ON and OFF end
Breaking Capacity Code:
J
Mercury Free:
Yes
Ik Degree Of Protection:
IK07 conforming to IEC 62262
Continuous Current Rating:
0.8
Quality Labels:
CE
Mechanical Durability:
15000 cycles IEC 947-1 Annex K ed 5.2
Environmental Disclosure:
ENVPEP2311047EN
Pollution Degree:
3 IEC 60947-1
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
9 Mm Pitches:
9