Circularity Profile:
ENVEOLI1501004
Ip Degree Of Protection:
IP2X front face VDE 0106
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
[Ui] Rated Insulation Voltage:
600 V UL || 600 V CSA || 690 V IEC 60947-5-1
Eu Rohs Directive:
Compliant with Exemptions
Device Short Name:
CAD
Mechanical Robustness:
shocks control relay open10 Gn for 11 ms IEC 60068-2-27 || shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 || vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6
Contactor Application:
control circuit
Connections - Terminals:
lugs-ring terminals 8 mm)
Inrush Power In Va:
70-70 VA 50 Hz (at 20°C)
Irms Rated Making Capacity:
140 A AC IEC 60947-5-1 || 250 A DC IEC 60947-5-1
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
[Icw] Rated Short-Time Withstand Current:
100 A - 1 s || 120 A - 500 ms || 140 A - 100 ms
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Control Circuit Type:
AC 50/60 Hz
Net Weight:
0.58 kg
Maximum Operating Rate:
180 cyc/mn
Hold-In Power Consumption In Va:
8-8 VA 50 Hz (at 20°C)
Height:
77 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Minimum Switching Voltage:
17 V
Pole Contact Composition:
5 NO
Utilisation Category:
AC-14 || DC-13 || AC-15
Mercury Free:
Yes
Ambient Air Temperature For Storage:
-60-80°C
Weight:
0.58 kg
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Non-Overlap Time:
1.5 ms on energisation between NC and NO contact || 1.5 ms on de-energisation between NC and NO contact
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Operating Altitude:
0...9842.52 ft (0...3000 m)
Mounting Support:
rail || plate
Rohs Exemption Information:
Yes
Insulation Resistance:
> 10 MOhm
Sustainable Offer Status:
Green Premium product
Depth:
84 mm
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C)
Associated Fuse Rating:
10 A gG conforming to IEC 60947-5-1
Minimum Switching Current:
5 mA
Range:
TeSys || TeSys Deca
Mechanical Durability:
30 Mcycles
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Product Name:
TeSys CAD
Operating Time:
12...22 ms coil energisation and NO closing || 4...12 ms coil de-energisation and NO opening
Standards:
EN/IEC 60947-5-1 || GB/T 14048.5 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || JIS C8201-5-1
[Ue] Rated Operational Voltage:
<= 690 V AC 25...400 Hz
Warranty:
18 months
Product Certifications:
CB || CCC || UL || CSA || EAC || CE || UKCA
$63.25

Description

TeSys D control relay, 5 contacts (5NO), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 230V 50/60Hz AC control circuit, connection by lugs. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium product (RoHS/REACh).