Schneider Electric

Schneider Electric HGF36045 Circuit breaker, PowerPacT H, 45A, 3 pole, 600VAC, 18kA, busbar, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
HGF36045
MPN:
HGF36045
Condition:
New
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Wire Stripping Length:
16 mm
Quality Labels:
CE
Length:
16 mm
Country of Origin:
United States
Device Application:
distribution
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Poles Description:
3P
Communication Interface:
Modbus || Ethernet
Pollution Degree:
3 IEC 60947-1
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Quantity Per Set:
1
Circularity Profile:
ENVEOLI2206027EN
Sustainable Offer Status:
Green Premium product
Mounting Support:
busbar
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Protected Poles Description:
3t
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Mercury Free:
Yes
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Network Frequency:
50/60 Hz
Environmental Disclosure:
ENVPEP2206027EN
Control Type:
toggle
Continuous Current Rating:
0.8
Suitability For Isolation:
yes IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Terminal Identifier:
AL150HD
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Product Or Component Type:
circuit breaker
Line Rated Current:
45-45 A
Warranty:
18 months
Depth:
86 mm
Ambient Air Temperature For Storage:
-50-85°C
Ambient Air Temperature For Operation:
-25-70°C
Height:
163 mm
Product Name:
PowerPact H
Pvc Free:
Yes
Utilisation Category:
category A
Magnetic Hold Current:
400 A
Trip Unit Technology:
thermal-magnetic
Color:
Black
Product Certifications:
UL || CSA || NOM
Ip Degree Of Protection:
front cover IP40 IEC 60529
Eu Rohs Directive:
Compliant with Exemptions
Range:
PowerPact
$1,493.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has a busbar connection. This PowerPacT H, 45A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose