Schneider Electric

Schneider Electric HLP36060 Circuit breaker, PowerPacT H, 60A, 3 pole, 600VAC, 50kA, lugs, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
HLP36060
MPN:
HLP36060
Condition:
New
Communication Interface:
Modbus || Ethernet
Color:
Black
Net Weight:
2.2 kg
Environmental Disclosure:
ENVPEP2206027EN
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Magnetic Tripping Current:
1450-1450 A
Pollution Degree:
3 IEC 60947-1
Quantity Per Set:
1
Breaking Capacity Code:
L
Warranty:
18 months
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Range:
PowerPact
Utilisation Category:
category A
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Line Rated Current:
60-60 A
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Circuit Breaker Application:
HACR rated
Product Or Component Type:
circuit breaker
Mounting Support:
lug
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Electrical Connection:
terminal nut, line || lugs, load
Network Frequency:
50/60 Hz
Rohs Exemption Information:
Yes
Pvc Free:
Yes
Trip Unit Technology:
thermal-magnetic
Product Certifications:
UL || CSA || NOM
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Control Type:
toggle
Mercury Free:
Yes
Eu Rohs Directive:
Compliant with Exemptions
Country of Origin:
Mexico
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Length:
16 mm
Local Signaling:
switched off (OFF) 1 trip indicator green)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Poles Description:
3P
Sustainable Offer Status:
Green Premium product
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Depth:
86 mm
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Magnetic Hold Current:
800 A
Circularity Profile:
ENVEOLI2206027EN
Mounting Mode:
unit mount lug)
Ip Degree Of Protection:
front cover IP40 IEC 60529
Width:
104 mm
Weight:
2.2 kg
Device Application:
distribution
$2,849.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has terminal nuts on the line side and lugs on the load side. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose