Schneider Electric LC1D09BNE IEC contactor, TeSys Deca Green, nonreversing, 9A, 5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24/60 VAC/VDC coil, open
Schneider Electric
$41.00
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.81 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
- Control Circuit Type:
- AC/DC 50/60 Hz AC/DC electronic
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Height:
- 77 mm
- Coil Technology:
- built-in bidirectional peak limiting
- Power Dissipation Per Pole:
- 1.56 W AC-1 || 0.2 W AC-3 || 0.2 W AC-3e
- Depth:
- 86 mm
- Operating Time:
- 45...55 ms closing || 20...90 ms opening
- Electrical Durability:
- 2.4 Mcycles 8 A AC-3 <= 440 V || 0.6 Mcycles 25 A AC-1 <= 440 V || 2.4 Mcycles 8 A AC-3e <= 440 V
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz
- Range:
- TeSys || TeSys Deca
- Maximum Horse Power Rating:
- 0.33 hp at 115 V AC 60 Hz for 1 phase motors || 1 hp at 230/240 V AC 60 Hz for 1 phase motors || 2 hp at 200/208 V AC 60 Hz for 3 phase motors || 2 hp at 230/240 V AC 60 Hz for 3 phase motors || 5 hp at 460/480 V AC 60 Hz for 3 phase motors || 7.5 hp
- Mounting Support:
- rail || plate
- [Icw] Rated Short-Time Withstand Current:
- 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms for Signaling circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Irms Rated Making Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Control Circuit Voltage Limits:
- <= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC || 0.8...1.1 Uc -40-60°C operational DC || 1...1.1 Uc 60-70°C operational AC/DC
- Width:
- 45 mm
- Warranty:
- 18 months
- Inrush Power In W:
- 14-14 W 20°C)
- [Ie] Rated Operational Current:
- 9 A (at <60°C) at <= 440 V AC-3 for power circuit || 25 A (at <60°C) at <= 440 V AC-1 for power circuit || 9 A (at <60°C) at <= 440 V AC-3e for power circuit
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
- Rohs Exemption Information:
- Yes
- Eu Rohs Directive:
- Compliant with Exemptions
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Contactor Application:
- motor control || resistive load
- Average Impedance:
- 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Fire Resistance:
- 850°C IEC 60695-2-1
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Weight:
- 0.368 kg
- Pole Contact Composition:
- 3 NO
- Device Short Name:
- LC1D
- Range Of Product:
- TeSys Deca
- Mechanical Durability:
- 15 Mcycles
- Mercury Free:
- Yes
- Connections - Terminals:
- control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Poles Description:
- 3P
- Utilisation Category:
- AC-1 || AC-3 || AC-3e
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || power
- Product Certifications:
- CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
- Hold-In Power Consumption In W:
- 0.6-0.6 W 20°C
- Heat Dissipation:
- 0.6-0.6 W at 50/60 Hz
- Net Weight:
- 0.368 kg
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Protective Cover:
- with