Schneider Electric LC1D386BD IEC contactor, TeSys Deca, nonreversing, 38A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
Schneider Electric
$241.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 38A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 25HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.98 inches deep. It weighs 1.19 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Signaling Circuit Frequency:
- 25...400 Hz
- Poles Description:
- 3P
- Country of Origin:
- Indonesia
- Time Constant:
- 28 ms
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
- Environmental Disclosure:
- ENVPEP110230EN
- Weight:
- 0.54 kg
- Mechanical Durability:
- 30 Mcycles
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Depth:
- 101 mm
- Power Dissipation Per Pole:
- 5 W AC-1 || 3 W AC-3 || 3 W AC-3e
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Flame Retardance:
- V1 conforming to UL 94
- Contactor Application:
- resistive load || motor control
- Protective Treatment:
- THIEC 60068-2-30
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Device Short Name:
- LC1D
- Rated Breaking Capacity:
- 550 A at 440 V for power circuit conforming to IEC 60947
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Eu Rohs Directive:
- Compliant with Exemptions
- Rohs Exemption Information:
- Yes
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Pollution Degree:
- 3
- Inrush Power In W:
- 5.4-5.4 W 20°C)
- Protective Cover:
- with
- Control Circuit Voltage Limits:
- 0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
- [Ie] Rated Operational Current:
- 50 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 38 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 38 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Mounting Support:
- rail || plate
- Compatibility Code:
- LC1D
- Mercury Free:
- Yes
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Sustainable Offer Status:
- Green Premium product
- Warranty:
- 18 months
- [Icw] Rated Short-Time Withstand Current:
- 60 A 40°C - 10 min for power circuit || 430 A 40°C - 1 s for power circuit || 150 A 40°C - 1 min for power circuit || 310 A 40°C - 10 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Fire Resistance:
- 850°C IEC 60695-2-1
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Maximum Horse Power Rating:
- 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 5 hp at 240 V AC 50/60 Hz for 1 phase motors || 20 hp at 480 V AC 50/60 Hz for 3 phase motors || 25 hp at 600 V AC 50/60 Hz for 3 phase motors
- Width:
- 45 mm
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Connections - Terminals:
- control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 10 mm
- Net Weight:
- 0.54 kg
- Overvoltage Category:
- III
- Circularity Profile:
- ENVEOLI1102030EN