Schneider Electric

Schneider Electric LC1D65U7 IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 240VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D65U7
MPN:
LC1D65U7
Condition:
New
Country of Origin:
United States
Power Dissipation Per Pole:
6.4 W AC-4 || 4.2 W AC-3e || 6.3 W AC-3 || 9.6 W AC-1
Width:
70 mm
Rated Breaking Capacity:
1000 kA at 440 V for power circuit conforming to IEC 60947
Pole Contact Composition:
3 NO
Protective Cover:
with
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Protective Treatment:
TH 3)IEC 60068-2-30
Climatic Withstand:
IACS E10 exposure to damp heat
Poles Description:
3P
Motor Power Kw:
11 kW at 400 V AC 50 Hz (AC-4) || 30 kW at 380...400 V AC 50 Hz (AC-3) || 37 kW at 500 V AC 50 Hz (AC-3) || 37 kW at 660...690 V AC 50 Hz (AC-3) || 18.5 kW at 220...230 V AC 50 Hz (AC-3) || 30 kW at 415 V AC 50 Hz (AC-3) || 37 kW at 1000 V AC 50 Hz (
[Ith] Conventional Free Air Thermal Current:
80 A (at 60°C) for power circuit || 10 A (at 60°C) for control circuit
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Insulation Resistance:
> 10 MOhm for control circuit
Product Or Component Type:
contactor
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Inrush Power In Va:
160-160 VA cos phi 0.75 (at 20°C) || 140-140 VA cos phi 0.75 (at 20°C)
Operating Altitude:
0...9842.52 ft (0...3000 m)
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Mechanical Robustness:
shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor opened 10 Gn for 11 ms)
Mounting Support:
plate || rail
Compatibility Code:
LC1D
Operating Time:
12...26 ms closing || 4...19 ms opening
Weight:
2.185 kg
Range Of Product:
TeSys Deca
Ip Degree Of Protection:
IP2X VDE 0106 || IP2X IEC 60529
Auxiliary Contacts Type:
mirror contact 1 NC IEC 60947-4-1 || mechanically linked 1 NO + 1 NC IEC 60947-5-1
Hold-In Power Consumption In Va:
15-15 VA 50 Hz cos phi 0.3 (at 20°C) || 13-13 VA 60 Hz cos phi 0.3 (at 20°C)
Maximum Operating Rate:
3600 cyc/mn 60°C
[Icw] Rated Short-Time Withstand Current:
520 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit
Non-Overlap Time:
1.5 ms on energisation between NC and NO contacts || 1.5 ms on de-energisation between NC and NO contacts
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Height:
122 mm
Flame Retardance:
V1 conforming to UL 94
Coil Technology:
without built-in
Pvc Free:
Yes
Mechanical Durability:
6000000 cycles
Sustainable Offer Status:
Green Premium product
[Uc] Control Circuit Voltage:
240 V AC 50/60 Hz
Net Weight:
2.185 kg
Average Impedance:
1.5 Ohm - Ith 80 A 50 Hz for power circuit
Safety Reliability Level:
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Overvoltage Category:
III
Utilisation Category:
AC-4 || AC-1 || AC-2 || AC-3e || AC-3
Standards:
EN 60947-4-1 || CSA C22.2 No 14 || IEC 60947-4-1 || EN 60947-5-1 || UL 508
Depth:
118 mm
Control Circuit Voltage Limits:
0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz || 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz
Irms Rated Making Capacity:
140 A at 440 V AC for control circuit conforming to IEC 60947-5-1 || 140 A AC for control circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
Mercury Free:
Yes
$532.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose