Schneider Electric

Schneider Electric LC1D95G7 IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D95G7
MPN:
LC1D95G7
Condition:
New
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.
Protective Cover:
with
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Operating Time:
20...35 ms closing || 6...20 ms opening
Hold-In Power Consumption In Va:
26-26 VA 60 Hz cos phi 0.3 (at 20°C) || 26-26 VA 50 Hz cos phi 0.3 (at 20°C)
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Pvc Free:
Yes
Electrical Durability:
1.2 Mcycles 95 A AC-3 || 1.3 Mcycles 125 A AC-1 || 1.2 Mcycles 95 A AC-3e
Poles Description:
3P
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 125 A (at 60°C) for power circuit
Overvoltage Category:
III
Control Circuit Type:
AC 50/60 Hz
Contactor Application:
resistive load || motor control
Motor Power Kw:
25 kW at 220...230 V AC 50 Hz (AC-3) || 45 kW at 380...400 V AC 50 Hz (AC-3) || 45 kW at 415...440 V AC 50 Hz (AC-3) || 55 kW at 500 V AC 50 Hz (AC-3) || 45 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 400 V AC 50 Hz (AC-4) || 25 kW at 220...230 V A
Insulation Resistance:
> 10 MOhm for Signaling circuit
Toxic Heavy Metal Free:
Yes
Signaling Circuit Frequency:
25...400 Hz
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Protective Treatment:
THIEC 60068-2-30
Sustainable Offer Status:
Green Premium product
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
Ip Degree Of Protection:
IP20 front face IEC 60529
Maximum Horse Power Rating:
7.5 hp at 120 V AC 60 Hz for 1 phase motors || 15 hp at 230/240 V AC 60 Hz for 1 phase motors || 30 hp at 200/208 V AC 60 Hz for 3 phase motors || 30 hp at 230/240 V AC 60 Hz for 3 phase motors || 60 hp at 460/480 V AC 60 Hz for 3 phase motors || 60
Environmental Disclosure:
ENVPEP110205EN
Irms Rated Making Capacity:
1100 A at 440 V AC for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Power Dissipation Per Pole:
12.5 W AC-1 || 7.2 W AC-3 || 7.2 W AC-3e
Coil Technology:
without built-in suppressor module
Depth:
130 mm
Average Impedance:
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Reach Free Of Svhc:
Yes
Compatibility Code:
LC1D
Mounting Support:
plate || rail
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Maximum Operating Rate:
3600 cyc/h 60°C
Rohs Exemption Information:
Yes
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Minimum Switching Voltage:
17 V for Signaling circuit
[Ie] Rated Operational Current:
95 A (at <60°C) at <= 440 V AC-3 for power circuit || 125 A (at <60°C) at <= 690 V AC-1 for power circuit || 95 A (at <60°C) at <= 440 V AC-3e for power circuit
Height:
127 mm
[Icw] Rated Short-Time Withstand Current:
1100 A 40°C - 1 s for power circuit || 800 A 40°C - 10 s for power circuit || 400 A 40°C - 1 min for power circuit || 135 A 40°C - 10 min for power circuit || 140 A - 100 ms for Signaling circuit || 120 A - 500 ms for Signaling circuit || 100 A - 1 s
Auxiliary Contact Composition:
1 NO + 1 NC
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
[Ui] Rated Insulation Voltage:
power circuit 1000 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Range:
TeSys
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
$437.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 95A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.55 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose