Schneider Electric LC1DT25F7 IEC contactor, TeSys Deca, nonreversing, 25A resistive, 4 pole, 4 NO, 110VAC 50/60Hz coil, open style
Schneider Electric
$159.60
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Pole Contact Composition:
- 4 NO
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Operating Time:
- 4...19 ms opening || 12...22 ms closing
- Signaling Circuit Frequency:
- 25...400 Hz
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Rated Breaking Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- [Uc] Control Circuit Voltage:
- 110 V AC 50/60 Hz
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Control Circuit Type:
- AC 50/60 Hz
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- Country of Origin:
- Indonesia
- Poles Description:
- 4P
- Flame Retardance:
- V1 conforming to UL 94
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Device Short Name:
- LC1D
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Electrical Durability:
- 0.8 Mcycles 25 A AC-1 <= 440 V
- Eu Rohs Directive:
- Compliant
- Coil Technology:
- without built-in suppressor module
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Rohs Exemption Information:
- Yes
- Utilisation Category:
- AC-1 || AC-3 || AC-3e || AC-4
- Circularity Profile:
- ENVEOLI1501004
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Pollution Degree:
- 3
- Environmental Disclosure:
- ENVPEP1501004
- Warranty:
- 18 months
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 250 A at 440 V for power circuit conforming to IEC 60947
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- [Ie] Rated Operational Current:
- 25 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Sustainable Offer Status:
- Green Premium product
- Weight:
- 0.365 kg
- Average Impedance:
- 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Mounting Support:
- rail || plate
- Toxic Heavy Metal Free:
- Yes
- Inrush Power In Va:
- 70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Range Of Product:
- TeSys Deca