- Ip Degree Of Protection:
- IP2X VDE 0106
- Utilisation Category:
- AC-1 || AC-3
- Maximum Operating Rate:
- 1200 cyc/h
- Weight:
- 0.132 kg
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Device Short Name:
- LC1SK
- Inrush Power In Va:
- 16-16 VA (at 20°C)
- Circularity Profile:
- ENVEOLI1503003EN
- Protective Treatment:
- TC IEC 60068 || TC DIN 50015
- Product Or Component Type:
- mini contactor
- Heat Dissipation:
- 1.4-1.4 W 50/60 Hz
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Pole Contact Composition:
- 2 NO
- Control Circuit Voltage Limits:
- operational: 0.85...1.1 Uc (at <50°C) || drop-out: 0.2...0.75 Uc (at <50°C)
- Product Name:
- TeSys SK
- Rohs Exemption Information:
- Yes
- Net Weight:
- 0.132 kg
- Average Impedance:
- 4 mOhm - Ith 12 A 50 Hz
- Range:
- TeSys
- Contactor Application:
- resistive load || motor control
- Standards:
- EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
- [Ith] Conventional Free Air Thermal Current:
- 12 A (at 55°C) for power circuit
- Rated Breaking Capacity:
- 52 A at <= 400 V for power circuit conforming to NF C 63-110 || 52 A at <= 400 V for power circuit conforming to IEC 60947
- Country of Origin:
- Czechia
- Product Certifications:
- CB Scheme || CE || UKCA || EAC || cULus
- Associated Fuse Rating:
- 16 A gI at <= 440 V for power circuit conforming to IEC 60947
- [Ie] Rated Operational Current:
- 6 A at <= 440 V AC AC-3 || 12 A (at <55°C) AC AC-1
- [Uc] Control Circuit Voltage:
- 24 V AC 50/60 Hz
- Mercury Free:
- Yes
- Ambient Air Temperature For Operation:
- -20-50°C
- Sustainable Offer Status:
- Green Premium product
- Mounting Support:
- rail
- Operating Time:
- 6...8 ms coil de-energisation and NO opening || 7...14 ms coil energisation and NO closing
- Mechanical Durability:
- 10 Mcycles
- [Icw] Rated Short-Time Withstand Current:
- 50 A 55°C for power circuit
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Eu Rohs Directive:
- Compliant with Exemptions
- Depth:
- 55.5 mm
- Hold-In Power Consumption In Va:
- 4.2-4.2 VA (at 20°C)
- Environmental Disclosure:
- ENVPEP1503003EN
- Control Circuit Type:
- AC 50/60 Hz
- Warranty:
- 18 months
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ui] Rated Insulation Voltage:
- 690 V IEC 60947 || 690 V VDE 0110 group C || 690 V BS 5424 || 690 V UL 508 || 690 V CSA C22.2 No 14
- Connections - Terminals:
- power circuit connector 1 0.35-6 mm²flexible with cable end || power circuit connector 1 0.5-6 mm²flexible without cable end || power circuit connector 1 1.5-6 mm²solid || power circuit connector 2 0.35-1.5 mm²flexible with cable end || power cir
- Irms Rated Making Capacity:
- 66 A at 690 V AC conforming to IEC 60947 || 66 A at 690 V AC conforming to NF C 63-110