Schneider Electric

Schneider Electric LC2D09KUE TeSys Deca reversing contactor - 3P - <= 440 V - 9 A AC-3 - 100...250 V AC/DC coil

(No reviews yet) Write a Review
SKU:
LC2D09KUE
MPN:
LC2D09KUE
Condition:
New
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Contactor Application:
motor control || resistive load
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
Coil Technology:
built-in bidirectional peak limiting
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Flame Retardance:
V1 conforming to UL 94
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rohs Exemption Information:
Yes
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Minimum Switching Current:
5 mA for Signaling circuit
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Product Or Component Type:
reversing contactor
Motor Power Kw:
2.2 kW at 220...230 V AC 50 Hz || 4 kW at 380...400 V AC 50 Hz || 4 kW at 415 V AC 50 Hz || 4 kW at 440 V AC 50 Hz || 5.5 kW at 500 V AC 50 Hz || 5.5 kW at 660...690 V AC 50 Hz
Heat Dissipation:
1.1-1.1 W 50/60 Hz
Electrical Durability:
2.4 Mcycles 8 A AC-3 <= 440 V || 0.6 Mcycles 25 A AC-1 <= 440 V || 2.4 Mcycles 8 A AC-3e <= 440 V
Maximum Operating Rate:
3600 cyc/h 60°C
Product Name:
Tesys Deca green || TeSys Deca
Device Short Name:
LC2D
Ambient Air Temperature For Storage:
-60-80°C
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Inrush Power In Va:
25-25 VA 50/60 Hz 20°C)
[Ie] Rated Operational Current:
9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 25 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 9 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Eu Rohs Directive:
Compliant with Exemptions
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Mercury Free:
Yes
Minimum Switching Voltage:
17 V for Signaling circuit
Net Weight:
0.783 kg
Hold-In Power Consumption In Va:
1.6-1.6 VA 20°C) 50/60 Hz
Inrush Power In W:
18-18 W 20°C
Interlocking Type:
mechanical
Range:
TeSys || TeSys Deca
Operating Altitude:
0...9842.52 ft (0...3000 m)
Device Presentation:
preassembled with reversing power busbar
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Signaling Circuit Frequency:
25...400 Hz
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Icw] Rated Short-Time Withstand Current:
105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Overvoltage Category:
III
Country of Origin:
France
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Environmental Disclosure:
ENVPEP1609001EN
Halogen Content Performance:
Halogen free plastic parts & cables product
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Warranty:
18 months
Maximum Horse Power Rating:
0.33 hp at 115 V AC 60 Hz for 1 phase motors || 1 hp at 230/240 V AC 60 Hz for 1 phase motors || 2 hp at 200/208 V AC 60 Hz for 3 phase motors || 2 hp at 230/240 V AC 60 Hz for 3 phase motors || 5 hp at 460/480 V AC 60 Hz for 3 phase motors || 7.5 hp
Protective Treatment:
TH IEC 60068-2-30
$113.00

Description

LC2D09KUE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 100-250V AC/DC low consumption electronic coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D09KUE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 4kW@400V. It includes a 100-250V AC/DC low consumption electronic coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 9A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.
View AllClose