Schneider Electric

Schneider Electric LP1K0601BD3 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 6A, 1 NC aux, 24VDC coil

(No reviews yet) Write a Review
SKU:
LP1K0601BD3
MPN:
LP1K0601BD3
Condition:
New
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Ambient Air Temperature For Storage:
-50-80°C
Depth:
57 mm
Poles Description:
3P
Heat Dissipation:
1.3-1.3 W
Toxic Heavy Metal Free:
Yes
Operating Altitude:
6561.68 ft (2000 m) without derating
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Auxiliary Contacts Type:
instantaneous 1 NC
Device Short Name:
LP1K
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Electrical Durability:
1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
Mechanical Durability:
10 Mcycles
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Insulation Resistance:
> 10 MOhm for Signaling circuit
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
[Ie] Rated Operational Current:
6 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 6 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Reach Regulation:
Free of Substances of Very High Concern above the threshold
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Utilisation Category:
AC-3 || AC-3e || AC-4
Country of Origin:
France
Overvoltage Category:
III
Net Weight:
0.225 kg
Product Or Component Type:
contactor
Rohs Exemption Information:
Yes
Motor Power Kw:
1.5 kW 220...230 V AC 50/60 Hz AC-3 || 2.2 kW 380...415 V AC 50/60 Hz AC-3 || 3 kW 440/690 V AC 50/60 Hz AC-3 || 1.5 kW 220...230 V AC 50/60 Hz AC-3e || 2.2 kW 380...415 V AC 50/60 Hz AC-3e || 3 kW 440/690 V AC 50/60 Hz AC-3e || 1.5 kW 220...230 V AC
Mounting Support:
plate || rail
Eu Rohs Directive:
Compliant
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Maximum Operating Rate:
3600 cyc/h
Minimum Switching Current:
5 mA for Signaling circuit
Ip Degree Of Protection:
IP2X
Reach Free Of Svhc:
Yes
Hold-In Power Consumption In W:
3-3 W 20°C
Operating Time:
30...40 ms coil energisation and NO closing || 10 ms coil de-energisation and NO opening
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Minimum Switching Voltage:
17 V for Signaling circuit
Contactor Application:
motor control
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
Warranty:
18 months
$85.00

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V). It provides a 24V DC coil with transient suppressor module, 1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose